| Model Name | CD_G_S_DC600 |
|
Rated power/kW |
600kW/720kW/960kW |
|
Charging pileW*D*H |
2200×800×1900mm |
|
Dual-gun terminalW*D*H |
600×360×1600mm |
|
AC input voltage |
Three-phase five-wire system 380VAC±15% |
|
Output voltage range |
200~1000VDC |
|
Operating ambient temperature |
Standard version:-20 ℃~55 ℃ High-altitude version:-40 ℃~55 ℃ |
|
Maximum output power per channel |
300KW |
|
Maximum output current per channel |
300A |
|
Gun line length |
Standard configuration 5m |
|
Voltage regulation accuracy |
≤±0.5% |
|
Steady flow accuracy |
≤±1% |
|
Protection level |
IP54 |
|
DC electricity meter accuracy class |
Level 1.0 |
|
BMSauxiliary voltage(V) |
12V/24V |
|
Cooling method |
Intelligent air cooling |
|
Operating humidity |
5%~95%No condensation |
|
Working altitude |
≤2000 m,Vehicles above 2000m require reduced usage. |
|
Internet connection method |
Ethernet port or 4G |
National Service Hotline
400-891-3100R&D Center: No. 207, Xingpu Road, Suzhou Industrial Park, Jiangsu Province
Mass production center: No. 2, Muer Road, Guangling District, Yangzhou City, Jiangsu Province
Website: www.enerax.cn
Email: business@enerax.com